How It Functions

What Is The NeosGuard Plus Man Down Device?

 

The NeosGuard Plus man down device is a revolutionary state of the art satellite locator that contains all useful and necessary functions for safety, protection and safeguard of people, things and animals.

The NeosGuard Plus man down device does not have optionals, it already contains all fundamental features for its function and for the safety measures that the user has the option to enable or not and does not require any particular installation.

The NeosGuard Plus man down device is easy to use and configure and our company provides support for any technical clarification and explanation on its function. For its main functions it needs only a normal telephone sim, not supplied, of any service provider.

The NeosGuard Plus man down device is:

    1. 100% designed and built in ITALY
    2. small in size
    3. easy to use, as its use is intuitive and requires no technical knowledge, and therefore can be used by everyone
    4. capable of detecting the posture of the person, thanks to the man down function
    5. capable of detecting the movement, or absence of movement, of the person thanks to the non-movement function
    6. capable of detecting the activity of the device thanks to its downtime function
    7. capable of detecting the position thanks to its state of the art high sensitivity GPS and to send it automatically or on request
    8. capable of sending alarms with an SMS or making voice calls
    9. capable of sending alarms with a customized pre-recorded message
    10. capable of sending help requests automatically, through the activation of the multiple functions with which it is equipped, or manually by pressing the central red button (SOS)
    11. equipped with the geo-fence function to create circular or polygonal virtual fences when configuring the device
    12. equipped with the auto geo-fence function to create circular virtual fences directly through the NeosGuard Plus man down device
    13. use of a normal telephone sim card of any service provider
    14. no subscription required
    15. BEFORE AND AFTER SALES SUPPORT

We will take care of everything

You Don’t Have Time To Configure It?
We Will Take Care Of Everything.

Just send us the configuration form and we will send it to your address already configured, and you will only need to insert the sim card inside, and your NeosGuard Plus man down device will be ready to protect you or the people close to you.

The 100% Italian device

NeosGuard Plus, dispositivo di sicurezza gps uomo a terra

How The NeosGuard Plus Device Functions

** Automatic Alarm Function

The automatic alarm of the NeosGuard Plus device occurs in the event of:

    1. the man down alarm is triggered
    2. the non-movement alarm is triggered
    3. the downtime alarm is triggered

The NeosGuard Plus man down device will notify the user with a vocal message, which alarm function has been
triggered, and if by chance it had been activated by mistake, it can simply be reset.

  • How to reset the man down function alarm

In order to reset the alarm triggered by the man down function, within the pre-alarm time set by default to 30
sec., the user of the NeosGuard Plus man down device has to simply return to an upright position.

  • How to reset the alarm of the non-movement function

In order to reset the alarm triggered by the non-movement function, within the pre-alarm time set by default to
30 sec., the user of the NeosGuard Plus man down device has to simply perform any slight movement.

  • How to reset the downtime alarm

In order to reset the alarm triggered by the downtime function, within the pre-alarm time set by default to 30
sec., the user of the NeosGuard Plus man down device has to simply press the A button on the device.

Once the pre-alarm time is over, the alarm procedure set on the NeosGuard Plus man down device will start, and the user will not be able to do anything to stop it.

** Manual Alarm Function

The manual alarm of the NeosGuard Plus man down device occurs if the device’s central red SOS button is pressed.

The NeosGuard Plus man down device will notify the user that the device is in pre-alarm, and if the SOS button was accidentally pressed, the alarm mode can simply be reset.

  • How to reset the manual alarm

In order to reset the triggered manual alarm simply press the B button, configured for this function (Alarm off).

** Alarm Mode Sending Function

The NeosGuard Plus man down device alarm can be triggered in the following ways:

  • from the man down function
  • from the non-movement function
  • from the downtime function
  • by pressing the SOS button

After that the NeosGuard Plus man down device alarm has been triggered, the man down system can send the alarm and the relative request for help in the following ways:

  • starts a cycle of calls
  • sends an SMS alarm
  • starts a cycle of calls and sends an SMS alarm simultaneously
  • starts a cycle of calls forwarding a standard recorded message
  • starts a cycle of calls forwarding a customized recorded message

** Alarm Sending Mode Function: Starting a Call Cycle

If the user has chosen to forward the distress call from the NeosGuard Plus man down device with the start of a cycle of calls, the device will start calling the configured numbers, a maximum of 5 numbers can be set, in the set sequence. The man down device will start calling the 1st number, and in the event of no answer it will immediately switch to the 2nd number, and so on. When one of the numbers takes the call, it is possible to talk to the recipient, if the user is able to do so, for a configurable time set by default to 90 sec., after which the man down device will go on calling the next number after waiting for the end of the alarm time set by default to 40 seconds.

What is the end of the alarm time? The end of the alarm time is the time that the man down device waits between a finished conversation, before moving on to calling the next number, so that the first person to answer the distress call, ensures that the next configured numbers are not called, the person has the necessary time to send an SMS message from their mobile phone to the NeosGuard Plus man down device to terminate the call cycle, with the following written:

psw:1234;termina

For those wishing to ensure that cyclic calls end after one of the numbers has answered, during the configuration it is also possible to configure this possibility.

** Alarm Sending Mode Function: SMS Alarm Sending

The user has chosen to forward the distress call from the NeosGuard Plus man down device by sending an alarm SMS, the device will start sending simultaneously to the configured numbers, a maximum of 5 numbers can be set, the pre-selected alarm message, at the configured time intervals, set by default to 60 sec.

The alarm messages that can be set, there are 2 types that can be chosen from:

  • the 1st SMS message does not contain the GPS position of where the device was located at the time the alarm was triggered
  • the 2nd SMS message contains the GPS position of where the device was located at the time the alarm was triggered

Both alarm messages contain the cause of the motive for the alarm.

The causes of the alarm can be the following:

    1. the alarm was triggered by pressing the SOS button
    2. the alarm was triggered by the man down function
    3. the alarm was triggered by the non-movement function
    4. the alarm was triggered by the downtime function

The first recipient, who will take the call sent via SMS from the NeosGuard Plus man down device, who will also want to interrupt the alarm mode and ensure that no other alarms are sent, must send from their mobile phone to the man down device an SMS message with the following writing:

psw:1234;allarme off

** Starting A Cycle Of Calls With A Recorded Message Function

If the user has chosen to forward the distress call from the NeosGuard Plus man down device with the start of a cycle of calls with a standard or customized recorded message, the device will start calling the configured numbers, a maximum of 5 numbers can be set, in the set sequence. The man down device will start calling the 1st number, and in the event of no answer it will immediately switch to the 2nd number, and so on. When one of the numbers takes the call, it is possible to talk to the recipient, if the user is able to do so, for a configurable time set by default to 90 sec., after which the man down device will go on calling the next number after waiting for the end of the alarm time set by default to 40 seconds.

What is the end of the alarm time? The end of the alarm time is the time that the man down device waits between a finished conversation, before moving on to calling the next number, so that the first person to answer the distress call, ensures that the next configured numbers are not called, the person has the necessary time to send an SMS message from their mobile phone to the NeosGuard Plus man down device to terminate the call cycle, with the following written:

psw:1234;termina

For those wishing to ensure that cyclic calls end after one of the numbers has answered, during the configuration it is also possible to configure this possibility.

** Check Device Function

The NeosGuard Plus device, with this check device function, if activated, will send an SMS message at a maximum of n. 2 recipients, indicating that the device is functioning regularly.

** Auto Answer Function

This function allows to automatically answer incoming calls. The NeosGuard Plus device will connect with the caller even if the user of the device is unable to answer the call alone. The automatic response time can be changed.